Max RCF: | 6060xg | Maximum Capacity: | 4x750ml |
---|---|---|---|
Speed Accuracy: | ± 10r/min | Net Weight: | 115Kg |
Temperature Setting Range: | -20~+40℃ | Power Supply: | AC220V 50Hz 15A |
Overall Dimensions (LxWxH): | 730mmx650mmx390mm | Overall Machine Noise: | ≤58dB(A) |
High Light: | Refrigerated Automatic Decapping Centrifuge,Low Temperature Automatic Decapping Centrifuge,Desktop Low Temperature Centrifuge |
TDL4-T Desktop Low Temperature Fully Automatic Decapping Centrifuge Refrigerated Type
Main technical performance
TDL4-T desktop low temperature fully automatic decapping centrifuge vacuum blood collection tube automatically decaps, the decapping success rate is 100%
The TDL4-T desktop low-temperature fully automatic decapping centrifuge is suitable for capping vacuum blood collection tubes in three lengths: 106/101/81mm.
The TDL4-T desktop low-temperature fully-automatic decapping centrifuge has a large screen and true color display, a humanized operation interface, and is simple and convenient to use.
The TDL4-T desktop low-temperature fully automatic decapping centrifuge has real-time reading conversion and setting between rpm/RCF, which is convenient and fast.
The TDL4-T desktop low-temperature fully automatic decapping centrifuge uses imported high-performance compressor fluorine-free refrigerant R404a, which meets environmental protection requirements and has good refrigeration effect.
The TDL4-T desktop low-temperature fully automatic decapping centrifuge adopts an electronic door lock, which is safe and reliable.
The TDL4-T desktop low-temperature fully-automatic decapping centrifuge adopts a special shock-absorbing structure with good shock-absorbing effect and has an automatic balancing function.
The TDL4-T desktop low-temperature fully automatic decapping centrifuge is equipped with multiple protection functions such as unbalance, overspeed, and door cover protection.
TDL4-T desktop low-temperature fully automatic decapping centrifuge has a maximum speed of 6000r/min and a maximum capacity of 4x750ml
The main technical parameters
Model | TDL4-T |
Maximum speed | 6000r/min |
Maximum relative centrifugal force | 6060xg |
Maximum capacity | 4x750ml |
Speed accuracy | ± 10r/min |
Time setting range | 1min~999min |
Temperature setting range | -20~+40℃ |
Temperature control accuracy | ±1℃ |
Overall machine noise | ≤58dB(A) |
Application areas | hospitals, blood stations, radioimmunoassay, nuclear medicine and other units |
Overall dimensions (LxWxH) | 730mmx650mmx390mm |
Net weight | 115Kg |
Adapted rotor parameters
Rotor number | Rotor type | Rotor capacity | Maximum speed | Max RCF | Adapter can be added |
1 | horn rotor | 12x15ml | 6000r/min | 6060xg | 10/5ml |
2 | horizontal uncapping rotor | 48x5/3/2ml | 4000r/min | 3180xg | |
3 | horizontal uncapping rotor | 64x5/3/2ml | 4000r/min | 3190xg | |
4 | horizontal uncapping rotor | 80x5/3/2ml | 4000r/min | 3190xg | |
5 | horizontal uncapping rotor | 96x5/3/2ml | 4000r/min | 3360xg | |
6 | horizontal uncapping rotor | 4x750/500ml | 4000r/min | 3580xg | 250/100/50/10/5ml |