Maximum Speed: | 5500r/min | Max RCF: | 5350×g |
---|---|---|---|
Speed Accuracy: | ±10r/min | Maximum Capacity: | 4×500ml |
Temperature Setting Range: | -20~+40℃ | Temperature Control Accuracy: | ±1℃/±0.5℃ |
Time Setting Range: | 1min~99min59sec/1sec~99min59sec | Net Weight: | 126kg |
Dimensions (LxWxH): | 730mm×650mm×390mm | Power Supply: | AC220V 50Hz 15A |
High Light: | Low Speed Refrigerated Table Top Centrifuge,Refrigerated Table Top Centrifuge 5500r/min |
TDL-5MC Desktop Low Speed Refrigerated Centrifuge
Main technical performance
·Microcomputer control, AC variable frequency motor drive, stable operation, low noise and high speed accuracy.
·≥7 inches high sensitivity (can be operated directly with gloves), resolution no less than (1024*600) high-definition touch screen control, easy operation and intuitive display;
·The setting parameters and operating parameters are displayed on the same screen, which is intuitive and easy to understand. By directly inputting the setting parameter values, the parameters can be set quickly, which is fast, convenient and fast;
·The centrifugal force and rotational speed can be automatically switched by pressing the button, and the rotational speed or centrifugal force can be quickly set.
·The timing mode has two modes: start timing or instant timing.
·Up to 10 groups of programs can be selected to realize step centrifugation, so that experiments can be diversified and performed in multiple steps at one time;
·Can set up ≥100 groups of programs, and each group of programs can be simply named, making it easier to retrieve and distinguish different experiments during use, and to facilitate the repeatability of experiments;
·≥11 acceleration gears, ≥12 deceleration gears; with customizable gears, acceleration and deceleration time can be customized according to experimental needs;
·≥2000 operation records and fault records are automatically saved, which can effectively check the operation status of the instrument and the separation status of each batch of samples
·The sleep time of the instrument can be set according to the time interval of the experiment; ensuring good cooling effect during the experiment; the instrument goes into sleep after the experiment, which is green and energy-saving, and increases the service life of the instrument;
Application areas
TDL-5MC desktop large-capacity refrigerated centrifuge is widely used in clinical medicine, biochemistry, genetic engineering, immunology and other fields. It is an essential instrument for centrifugal separation in comparative hospitals, scientific research units, and universities.
The main technical parameters
model | TDL-5MC |
Maximum speed | 5500r/min |
Maximum relative centrifugal force | 5350×g |
Maximum capacity | 4×500ml |
Speed accuracy | ±10r/min |
Time setting range | 1min~99min59sec/1sec~99min59sec |
Temperature setting range | -20~+40℃ |
Temperature control accuracy | ±1℃/±0.5℃ |
compressor unit | Imported high-performance compressor unit, environmentally friendly refrigerant R404a |
Machine noise | ≤65dB(A) |
power supply | AC220V 50Hz 15A |
Overall dimensions (LxWxH) | 730mm×650mm×390mm |
net weight | 126kg |
Adaptation of rotor parameters
Rotor type | Rotor capacity | Maximum speed | Maximum relative centrifugal force | Additional adapters available |
No. 1 corner rotor | 12×10/15ml | 5500r/min | 5350×g | 5/1.5/2.2ml |
No. 2 horizontal rotor | 24/32×15ml | 4500r/min | 3560×g | 10/5/2ml |
No. 3 horizontal rotor | 48/76×3/5ml | 4000r/min | 2915×g | 3/5ml vacuum blood collection tube universal |
No. 4 horizontal roto | 4/8×50/100ml | 4000r/min | 2915×g | 10/5/2ml |
No. 5 horizontal rotor | 96×3/5ml | 4000r/min | 2927×g | 3/5ml vacuum blood collection tube universal |
No. 6 horizontal rotor | 108×3/5ml | 4000r/min | 3580×g | 3/5ml vacuum blood collection tube universal |
No. 7 horizontal rotor | 120×3/5ml | 4000r/min | 3580×g | 3/5ml vacuum blood collection tube universal |
No. 8 horizontal rotor | 4×250/500ml | 4000r/min | 3050×g | 5/7/10/50/100ml |